Technical Articles

What is EN ISO 10993-24:2021?

EN ISO 10993-24:2021 is an international standard that provides guidance on the evaluation of medical devices for their potential to cause irritation and skin sensitization. This standard is part of a series of standards that focus on biocompatibility testing of medical devices, ensuring patient safety and regulatory compliance.

Understanding Irritation and Skin Sensitization

Irritation refers to a non-allergic, inflammatory response that occurs when the skin or mucous membranes are exposed to a substance. It usually manifests as redness, swelling, itching, or pain at the site of exposure. On the other hand, skin sensitization is an allergic response to a specific substance that causes an immune reaction in susceptible individuals. These reactions can range from mild itching and redness to severe blistering or even systemic reactions.

Evaluating Medical Devices

The evaluation of medical devices according to EN ISO 10993-24 involves performing tests to assess the potential for irritation and skin sensitization. These tests involve direct contact of the device or its extracts with the skin or mucous membranes. The severity of the reaction, if any, is assessed based on visual observations, such as erythema (redness) and edema (swelling), and subjective evaluations, including itchiness or discomfort reported by patients.

This standard also considers possible chemical interactions between the device and the skin by assessing the leachable substances that may cause irritation or sensitization. Chemical characterization and risk assessment are essential steps in complying with EN ISO 10993-24.

Significance in the Medical Device Industry

EN ISO 10993-24 plays a vital role in ensuring the safety and efficacy of medical devices. Adhering to this standard not only helps manufacturers meet regulatory requirements but also protects patients from potential harm. By evaluating the potential for irritation and sensitization, medical device developers can identify and mitigate risks early in the design and development process.

The standard applies to all types of medical devices that come into contact with the skin or mucous membranes, such as bandages, implants, dressings, and catheters. Compliance with EN ISO 10993-24 is crucial when seeking regulatory approvals or certifications for medical devices in various markets worldwide.

Conclusion

EN ISO 10993-24:2021 is an important international standard that focuses on assessing the potential for irritation and skin sensitization caused by medical devices. By following the guidelines outlined in this standard, medical device manufacturers ensure the safety and well-being of patients while complying with regulatory requirements. It is essential for companies in the medical device industry to understand and adhere to this standard to provide safe and effective products.

CATEGORIES

CONTACT US

Contact: Nina She

Phone: +86-13751010017

E-mail: sales@china-gauges.com

Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China

Scan the qr codeclose
the qr code